PS-10

PS-10

Power Management

This configuration can be argued as being the best combination available for providing pure and precise 240 volts to your valuable electrical equipment. Equipment that was designed to run on 240 volt power ensuring you get maximum performance and enjoyment for many years. When it comes to minimizing risk, we make no wild or glossy promises. Our products do what they say they do - it is that simple!

• Double Filtration And Double Protection Combination Equals Total Power Management
• Pure Unpolluted 240V Sinewave Power 24/7
• Soft Start - Gentle Power Build Up
• Whisper Quiet Servo Motor For Voltage Calibration
• Microprocessor Controls
• Dual Led Display Indicating Incoming Power And Output Power
• 10 Other Led Alerts Showing Various Power Changes Instantly
• Frontline Filtering And Surge Protection Through Power Station
• Double Filter Trap And Double Voltage Protection Through Custom 8 Way Smart Board
• Incorporating Dynamic Active Tracking Filtering Technology
• 3 In 1 Isolation
• 8 Outlets • Data & Aerial Protection
• Cable TV Adaptor
• Fibre Optic & Broadband Compatible !

Supply Voltage 240/Vac 50/Hz
Maximum Current Rating 10amps/2400 W (Va)
Wave Form Pure Sine Wave
Operating Voltage 160V - 270V
Output 240V
Incoming Voltage out of designed range (i.e. 160 - 270v) If input voltage was 295V then output would be approx 250 to 255V If input voltage was 140V then output would be approx 230 to 235V
Double Filtration and Protection Management A12 Smart Board included

 
 

Additional information availableProduct ImageAdditional information available

 
 

A12

A12

Smart Board Computer/Home Theatre

• Intelligent Power Conditioning Filter
• Dynamic Active Tracking Circuitry
• 3 In 1 Isolation
• Bank 1 = 1 outlet Bank 2 = 3 outlets Bank 3 = 4 outlets
• 8 Outlets
• All in the one compact board
• Data & Aerial Protection With Cable TV Adaptor
• Fibre Optic And Broadband Compatible
• Multiple Application Identity Tags

Supply Voltage 240/Vac 50/Hz
Maximum Current Rating 10amps/2400 W (Va)
Clamping Voltage 275Vac
Reaction Time Less than 1 Nano Sec
Maximum Transient Spike Impulse Current (AMPS) 208,000 amps. Equivalent to 52,000 amps using UL1449 Std
Maximum Energy Dissipation (Joules) 6080 Joules. Equivalent to 2050 Joules using UL1449 Std
Protection Modes Active/Neutral, Active/Earth, Neutral/Earth(all 8 outlets Protects on all 3 conductors)
EMI/RFI Noise Reduction Filter Type 38 separate protection components in 3 cascading circuits
Number of Multi-Stage Filter Banks 3 Number of Isolated Banks 3 Number of dedicated Outlets 4+3+1
Total Number of Protected AC Outlets 8 protected outlets
Incoming Telephone Line Protection (DC) with Inline Splitter (1 in - 2 out) RJ 1 Line in /2 lines out, RJ45 Internet/Network ready
Incoming Television Aerial protection (DC) with inline splitter 1 Line in /2 lines out
Cable TV 'F' type adaptor yes
Earth leakage Range Less than 1 milli amp
Operating conditions Indoor / AC Mains
Operating Temperatures - 10C/+60C
Cable length 1.8m

 
 

Additional information availableProduct ImageAdditional information available

 
 

D1-45

Smart Filter

• Universal Entry Level Range. Ideal for home office, computer, home theatre, sewing machines, fridges, washing machines and so on.
• 7 Filtered & Surge protected outlets - The most outlets in its class.
• Internet Ready - Ultra Fast Protection for your communication line - RJ 45 connection.
• 6-year genuine replacement warranty - even if damaged by lightning.
• Unique identity tags for cables - no more guessing which plug to pull - pre-printed tags for every cable

Supply Voltage 240/Vac 50/Hz
Maximum Current Rating 10amps/2400 W (Va)
Clamping Voltage 275Vac
Reaction Time Less than 1 Nano Sec
Maximum Transient Spike Impulse Current (AMPS) 156,000 amps or 39,000 amps using UL1449 Std
Maximum Energy Dissipation (Joules) 4588 Joules or 1550 Joules using UL1449 Std
Protection Modes Active/Neutral Active/Earth Neutral/Earth(all 7 outlets Protects on all 3 conductors)
EMI/RFI Noise Reduction Filter Type Entry Level
Total Number of Protected AC Outlets 7 filtered & protected outlets, Internet ready.
Earth leakage Range Less than 1 milli amp
Operating conditions Indoor / AC Mains
Operating Temperatures - 10C/+60C
Cable length 1.2m

 
 

Additional information availableProduct ImageAdditional information available

 
 

C-2

C-2

Smart Filter Duo

• Ideal for home office, computer, home theatre, sewing machines, fridges, washing machines and so on.
• 2 Filtered & Surge protected outlets - Included is a bonus 1 metre extension cord. This allows greater flexibility when connecting equipment that is not quite close enough to the power outlet.
• Featuring Thor's very own space saving "flat head" plug. Designed to fit behind fridges, washing machines etc.
• Earth detection circuit

Supply Voltage 240/Vac 50/Hz
Maximum Current Rating 10amps/2400 W (Va)
Clamping Voltage 275Vac
Reaction Time Less than 1 Nano Sec
Maximum Transient Spike Impulse Current (AMPS) 42,000 amps or 14,000 amps using UL1449 Std
Maximum Energy Dissipation (Joules) 1880 Joules or 360 Joules using UL1449 Std
Protection Modes (both outlets Protects on all 3 conductors) Active/Neutral Active/Earth Neutral/Earth
EMI/RFI Noise Reduction Filter Yes
Total Number of Protected AC Outlets 2 filtered & protected outlets
Earth Detection Circuit Yes
Earth Potential Rise Protection Yes
Earth leakage Range Less than 1 milli amp
Operating conditions Indoor / AC Mains
Operating Temperatures - 10C/+60C

 
 

No additional information availableProduct ImageAdditional information available

 
 

CM-90

CM-90

Hardwired Local

• High Capacity premium series active tracking (cavity mountable)
• AC Mains Filter + Surge protection isolation module
• Available 16Amp models

Supply Voltage 240/VAC 50/Hz
Maximum Current Rating 16amps/3840 W (Va)
Clamping Voltage 275Vac
Reaction Time Less than 1 Nano Sec
Maximum Transient Spike Impulse Current (AMPS) 49,000 amps Maximum Energy Dissipation (Joules) 1330 Joules
EMI/RFI Noise Reduction Filter Type Incorporating 16 separate protection components
Total Number of Protected AC Outlets 1 to 4 wall plates
Earth leakage Range Less than 1 milli amp
Operating conditions Indoor / AC Mains
Operating Temperatures - 10C/+60C Protection Modes (all 8 outlets Protects on all 3 conductors) Active/Neutral

 
 

No additional information availableProduct ImageAdditional information available

 
 

DRM-95/20

DRM-95/20

Hardwired Rail Mount

• High Capacity premium series active tracking filter
• AC Mains Filter + Surge protection isolation module
• Available 20Amp & 30 Amp models

Supply Voltage 240/VAC 50/Hz
Maximum Current Rating 20amps/4800 W (Va)
Clamping Voltage 275Vac
Reaction Time Less than 1 Nano Sec
Maximum Transient Spike Impulse Current (AMPS)
49,000 amps
Maximum Energy Dissipation (Joules) 1330 Joules
EMI/RFI Noise Reduction Filter Type Dynamic Active Tracking - Active Filter
Protected AC Incorporating 32 separate protection components
Earth leakage Range Less than 1 milli amp
Operating conditions Indoor / AC Mains
Operating Temperatures - 10C/+60C
Protection Modes on all 3 conductors Active/Neutral/Earth
For Qualified, licensed electrician installation only

 
 

No additional information availableProduct ImageAdditional information available

 
 

DRM-95/30

DRM-95/30

Hardwired Rail Mount

• High Capacity premium series active tracking filter
• AC Mains Filter + Surge protection isolation module
• Available 20Amp & 30 Amp models

Supply Voltage 240/VAC 50/Hz
Maximum Current Rating 30amps/7200 W (Va)
Clamping Voltage 275Vac
Reaction Time Less than 1 Nano Sec
Maximum Transient Spike Impulse Current (AMPS)
49,000 amps
Maximum Energy Dissipation (Joules) 2320 Joules
EMI/RFI Noise Reduction Filter Type Dynamic Active Tracking - Active Filter
Protected AC Incorporating 32 separate protection components
Earth leakage Range Less than 1 milli amp
Operating conditions Indoor / AC Mains
Operating Temperatures - 10C/+60C
Protection Modes on all 3 conductors Active/Neutral/Earth
Enclosure Wide din rail 105mm
For Qualified, licensed electrician installation only

 
 